Protection & Controls
Protection & Control Systems
Field commissioning, inspection, and troubleshooting of complete protection and control systems: relay logic, IEC 61850 communications, time synchronization, and the schemes that tie them together.
Scope
Logic · communications · timing · schemes
Deliverable
Documented system validation reports
Standards
IEC 61850 · IEEE 1588 · ANSI/NETA
Service Overview
Relays, logic, and networks verified as one system.
Modern protection depends on more than the relay. Logic, communications, and time sources must perform together. NewEra Testing validates the full protection and control system in the field: programmable logic, GOOSE messaging integrity, time synchronization, and communication architecture. We diagnose protocol-level issues, analyze fault events, and inspect panels and wiring, then document each finding with verified results.
Equipment covered
Multifunction protective relays
Relay and control panels
Bay controllers and RTUs
Substation gateways and data concentrators
Station Ethernet networks
GPS clocks and time servers
Lockout and auxiliary relays
DC control and trip circuits
Transfer and interlock schemes
Testing & Capabilities
System-level validation, from logic to network
Protection schemes depend on logic, messaging, and timing working together. We test each layer in place and prove the interactions between them.
Applicable Standards
Performed to recognized industry standards.
IEC 61850
Communication networks and systems for power utility automation
IEEE 1588
Precision Clock Synchronization Protocol for Networked Measurement and Control Systems
IEEE C37.2
Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations
ANSI/NETA ATS
Acceptance Testing Specifications for Electrical Power Equipment and Systems
ANSI/NETA MTS
Maintenance Testing Specifications for Electrical Power Equipment and Systems
From the Field



Methodology
How every job runs.

Related Services
Related services

01
Protective Relay Testing & Commissioning
Field testing and commissioning of protective relays: settings applied and verified, protection functions proven by secondary injection, and trip paths confirmed end to end.
View service →

03
Secondary Injection Testing
Three-phase secondary injection testing of protective relays. Pickup, timing, and logic verified across overcurrent, differential, and distance elements, documented to ANSI/NETA test specifications.
View service →

09
Troubleshooting & Fault Analysis
Field troubleshooting and fault event analysis for protection, control, and power distribution systems. We isolate root causes, verify corrections, and document every finding.
View service →
FAQs